Series 1000

Reaching The Pinnacle

    The P000 series five-cylinder piston pump theoretically handles input power of up to 1000 horsepower (735 kW). Unlike the P750 series, the P1000 series features a piston stroke increased from 127mm to 135mm, ranging from a minimum output pressure of 10,877 psi at 105.93 gallons per minute (at 750 bar, it’s 401 L/min) to a maximum pressure of 40,000 psi at 27.79 gallons per minute (at 2750 bar, it’s 105.2 L/min).

Technical parameters

Maximum input power

1000HP

Connectiontype

Direct connection

Plunger

5

Max input sppeed

1650 R·P·M

Reductioon ratio

1:3.636

Revolution speed

450 R·P·M

Gear oil

19.8 GPM

Type of gear oil

85W-90

Weight

Performance range

Note:

1 Bar = 0.1 MPa = 14.5 Psi

1 L/Min = 0.06 m³/H = 0.264 Gpm

1 kW = 1.36 Hp

The flow values provided here refer to “theoretical” flow and do not account for efficiency reduction due to water compressibility and expansion of pressurized components.

Within this performance range, you can match your engine power according to your specific needs. Please note that piston diameter, stroke, and other factors have not been considered here, so the flow rate may be higher than the actual flow rate.


Fluid End Specs

Plunger
Pump Model
Plunger Pump
Model Size
The Corresponding Flow
Rate At A Specific
Pump Speed
Rated Working
Pressure
Plunger ModelDiameter(Mm)Stroke(Mm)400 R P M/Min450 R P M/MinBar
P1000-40k-20#0202013584.5 L/Min95 L/Min2750
P1000-40k-21#0212113593 L/Min105 L/Min2750
P1000-35k-22#02222135102 L/Min115 L/Min2500
P1000-30k-25#02525135132 L/Min149 L/Min2000
P1000-25k-27#02727135154 L/Min174 L/Min1700
P1000-20k-30#03030135190 L/Min215 L/Min1400
P1000-15k-36#03636135259 L/Min292 L/Min1000
P1000-10k-42#04242135355401 L/Min750